Fire Escapes Dallas

Slide
Balconies • Decks • Fire Escapes
And other Exterior Elevated Elements
Slide
PlayPlay
Fire Escape Engineers

Balcony Inspections
Deck Inspections
Fire Escape Inspections
Ladder Inspections
Fire Escape Load Tests

Slide
PlayPlay
PlayPause
previous arrow
next arrow

Fire Escape Inspection Videos Texas

Fire Escape Code Dallas TX

Sec. 791.016. PAINTING AND MAINTENANCE REQUIREMENTS.

(a) A fire escape constructed of iron or steel must be painted with at least two coats of good metallic paint when erected. The fire escape must be repainted at least every two years or more frequently if necessary to preserve the fire escape from rust or climatic influences.

(b) The slideway of a straight or spiral chute fire escape must be thoroughly cleaned and painted at least once each year.

Acts 1989, 71st Leg., ch. 678, Sec. 1, eff. Sept. 1, 1989.

click here for entire code

2012 IFC 1104.16.5.1 Fire escape stairs must be examined every 5 years ,by design professional or others acceptable and inspection report must be submitted to the fire code official.

IBC 1001.3.3 All fire escapes shall be examined and/or tested and certified every five years by a design professional or others acceptable who will then submit an affidavit city official.

NFPA LIFE SAFETY CODE 101  7.2.8.6.2 The Authority Having Jurisdiction (AHJ) shall approve any fire escape by Load Test or other evidence of strength (Certification).

OSHA 1910.37 Exit routes must be maintained during construction, repairs, alterations or provide alternative egress with equivalent level of safety. (permit issued if egress is certified or with egress scaffolding) 

FIVE STEPS to Certify a Fire Escape:

  1. Schedule a pre load test evaluation by a design professional or others acceptable by City Official – AHJ (Authority Having Jurisdiction)
  2. Said professional will confirm with City Official if there are any other requirements other than load testing or other evidence of strength and if City Official wants to witness initial evaluation
  3. Submit evaluation report to owner/agent and a copy to the City Official as per code
  4. Issue certification, if passed, done by load test or other evidence of strength to City Official or, if failed, owner/agent and city official to confirm next steps (ex. engineer oversight, permits or other conditions)
  5. Please contact your local City Official (AHJ) with any questions about the above steps

——

Send us photos of your fire escape by email:

Click here to submit photo/videos via an online form for a free evaluation.