04.16.5.1 Examination. Fire escape stairways and balconies shall be examined for structural adequacy and safety in accordance with Section 1104.16.5 by a registered design professional or others acceptable to the fire code official every 5 years, or as required by the fire code official. An inspection report shall be submitted to the fire code official after such examination.

In California on January 1, 2019 SB 721 went into effect applies to apartment buildings with three or more units.

Also California SB 326, signed in 2019, applies to community associations or condominiums with three or more attached units.
Slide
PlayPlay
previous arrow
next arrow

2022 California Fire Code, Title 24, Part 9 CHAPTER 10 MEANS OF EGRESS

Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress.

(BE] 1028.2 Exit discharge.

Exits shall discharge directly to the exterior of the building. The exit discharge shall be at grade or shall provide a direct path of egress travel to grade.

1032.2.1.3 Examination.

Fire escape stairways and balconies shall be examined for structural adequacy and safety by a registered design

The examination shall determine

whether the fire escape stairways and balconies can support
pounds per square foot ( 4. 78 kN/m) An inspection report shall be submitted to the fire code official after such examination.

(BE] 1028.5 Access to a public way.
The exit discharge shall provide a direct and unobstructed access to a public way

3312.2 Maintenance.

Required means of egress and required accessible means of egress shall be maintained during construction and demolition, remodeling or alterations and additions to any building.
Exception: Approved temporary means of egress and accessible means of egress systems and facilities.


SEC 604

Requires apartment house (including residential condominium of 3 dwellings or more) and hotel (6 guest rooms or more) owners to have

all building appendages to be inspected by a licensed general contractor, or structural pest control licensee, or licensed professional architect or engineer,

verifying that the exit system, corridor, balcony, deck or any thereof is in general safe condition, in adequate working order, and free from hazardous dry rot, fungus, deterioration, decay, or improper alteration.

Property owners shall provide proof of compliance with this section by submitting an affidavit form (provided by the Department) signed by the responsible inspector to the Housing Inspection Services Division every five years.

SEC. 908. MAINTENANCE AND REPAIR

[Added by Ord. 399-89, App. 1 1/6/89; amended by Ord. 161-92, App. 6/4/92; Ord. 192-02, App. 9/17/02; Ord. 256-07, App. 11/6/07] 

All safety devices or equipment provided for in this chapter shall be maintained in good repair at all times. Fire escapes shall be kept clear and unobstructed and be readily accessible at all times. Upon inspection, the property owner, or authorized agent, shall demonstrate to the Director or designated personnel, that all existing fire escapes are fully operational and properly maintained. Upon completion of the inspection, all existing fire escapes shall be secured pursuant to Section 1110.3.1. of the San Francisco Fire Code.


NATIONAL CODES:

IFC 2015 1104.16 Fire Escape PDF copy actual code

2012 IFC 1104.16.5.1 Fire escape stairs must be examined every 5 years ,by design professional or others acceptable and inspection report must be submitted to the fire code official.

IBC 1001.3.3 All fire escapes shall be examined and/or tested and certified every five years by a design professional or others acceptable who will then submit an affidavit city official.

NFPA LIFE SAFETY CODE 101  7.2.8.6.2 The Authority Having Jurisdiction (AHJ) shall approve any fire escape by Load Test or other evidence of strength (Certification).

OSHA 1910.37 Exit routes must be maintained during construction, repairs, alterations or provide alternative egress with equivalent level of safety. (permit issued if egress is certified or with egress scaffolding) 



Senate Bill No. 721

CHAPTER 445

An act to amend Section 1954 of the Civil Code, and to add Article 2.2 (commencing with Section 17973) to Chapter 5 of Part 1.5 of Division 13 of the Health and Safety Code, relating to building standards.

[ Approved by Governor September 17, 2018. Filed with Secretary of State September 17, 2018. ]

LEGISLATIVE COUNSEL’S DIGEST

SB 721, Hill. Building standards: decks and balconies: inspection.

Existing law provides authority for an enforcement agency to enter and inspect any buildings or premises whenever necessary to secure compliance with or prevent a violation of the building standards published in the California Building Standards Code and other rules and regulations that the enforcement agency has the power to enforce.

This bill would require an inspection of exterior elevated elements and associated waterproofing elements, as defined, including decks and balconies, for buildings with 3 or more multifamily dwelling units by a licensed architect, licensed civil or structural engineer, a building contractor holding specified licenses, or an individual certified as a building inspector or building official, as specified. The bill would require the inspections, including any necessary testing, to be completed by January 1, 2025, with certain exceptions, and would require subsequent inspections every 6 years, except as specified. The bill would require the inspection report to contain specified items and would require that a copy of the inspection report be presented to the owner of the building within 45 days of the completion of the inspection and would require copies of the reports to be maintained in the building owner’s records for 2 inspection cycles, as specified. The bill would require that if the inspection reveals conditions that pose an immediate hazard to the safety of the occupants, the inspection report be delivered to the owner of the building within 15 days and emergency repairs be undertaken, as specified, with notice given to the local enforcement agency. The nonemergency repairs made under these provisions would be required to be completed within 120 days, unless an extension is granted by the local authorities. The bill would authorize local enforcement agencies to recover enforcement costs associated with these requirements. The bill would require the local enforcement agency to send a 30-day corrective notice to the owner of the building if repairs are not completed on time and would provide for specified civil penalties and liens against the property for the owner of the building who fails to comply with these provisions. The bill would exclude a common interest development, as defined, from these provisions. The bill would require any building subject to these provisions that is proposed for conversion to condominiums to be sold to the public after January 1, 2019, to have the required inspection conducted prior to the first close of escrow of a separate interest in the project, and would require the inspection report and written confirmation by the inspector that any recommended repairs or replacements have been completed to be submitted to, among others, the Department of Real Estate and included in certain required statements and reports, as specified. The bill would authorize a local governing entity to enact stricter requirements than those imposed by these provisions.

Existing law authorizes a landlord to enter the dwelling only in certain situations, including to make necessary repairs.

This bill would additionally authorize a landlord to enter the dwelling unit to comply with the above-described requirements.

Because this bill would impose new duties upon local enforcement authorities, it would impose a state-mandated local program.

The California Constitution requires the state to reimburse local agencies and school districts for certain costs mandated by the state. Statutory provisions establish procedures for making that reimbursement.

This bill would provide that no reimbursement is required by this act for a specified reason.

DIGEST KEY

Vote: majority   Appropriation: no   Fiscal Committee: yes   Local Program: yes  


BILL TEXT

THE PEOPLE OF THE STATE OF CALIFORNIA DO ENACT AS FOLLOWS:

SECTION 1.

 Section 1954 of the Civil Code is amended to read:

1954.

 (a) A landlord may enter the dwelling unit only in the following cases:

(1) In case of emergency.

(2) To make necessary or agreed repairs, decorations, alterations or improvements, supply necessary or agreed services, or exhibit the dwelling unit to prospective or actual purchasers, mortgagees, tenants, workers, or contractors or to make an inspection pursuant to subdivision (f) of Section 1950.5.

(3) When the tenant has abandoned or surrendered the premises.

(4) Pursuant to court order.

(5) For the purposes set forth in Chapter 2.5 (commencing with Section 1954.201).

(6) To comply with the provisions of Article 2.2 (commencing with Section 17973) of Chapter 5 of Part 1.5 of Division 13 of the Health and Safety Code.

(b) Except in cases of emergency or when the tenant has abandoned or surrendered the premises, entry may not be made during other than normal business hours unless the tenant consents to an entry during other than normal business hours at the time of entry.

(c) The landlord may not abuse the right of access or use it to harass the tenant.

(d) (1) Except as provided in subdivision (e), or as provided in paragraph (2) or (3), the landlord shall give the tenant reasonable notice in writing of his or her intent to enter and enter only during normal business hours. The notice shall include the date, approximate time, and purpose of the entry. The notice may be personally delivered to the tenant, left with someone of a suitable age and discretion at the premises, or, left on, near, or under the usual entry door of the premises in a manner in which a reasonable person would discover the notice. Twenty-four hours shall be presumed to be reasonable notice in absence of evidence to the contrary. The notice may be mailed to the tenant. Mailing of the notice at least six days prior to an intended entry is presumed reasonable notice in the absence of evidence to the contrary.

(2) If the purpose of the entry is to exhibit the dwelling unit to prospective or actual purchasers, the notice may be given orally, in person or by telephone, if the landlord or his or her agent has notified the tenant in writing within 120 days of the oral notice that the property is for sale and that the landlord or agent may contact the tenant orally for the purpose described above. Twenty-four hours is presumed reasonable notice in the absence of evidence to the contrary. The notice shall include the date, approximate time, and purpose of the entry. At the time of entry, the landlord or agent shall leave written evidence of the entry inside the unit.

(3) The tenant and the landlord may agree orally to an entry to make agreed repairs or supply agreed services. The agreement shall include the date and approximate time of the entry, which shall be within one week of the agreement. In this case, the landlord is not required to provide the tenant a written notice.

(e) No notice of entry is required under this section:

(1) To respond to an emergency.

(2) If the tenant is present and consents to the entry at the time of entry.

(3) After the tenant has abandoned or surrendered the unit.

SEC. 2.

 Article 2.2 (commencing with Section 17973) is added to Chapter 5 of Part 1.5 of Division 13 of the Health and Safety Code, to read:

Article  2.2. Exterior Elevated Elements: Inspections.
17973.

 (a) Exterior elevated elements that include load-bearing components in all buildings containing three or more multifamily dwelling units shall be inspected. The inspection shall be performed by a licensed architect; licensed civil or structural engineer; a building contractor holding any or all of the “A,” “B,” or “C-5” license classifications issued by the Contractors’ State License Board, with a minimum of five years’ experience, as a holder of the aforementioned classifications or licenses, in constructing multistory wood frame buildings; or an individual certified as a building inspector or building official from a recognized state, national, or international association, as determined by the local jurisdiction. These individuals shall not be employed by the local jurisdiction while performing these inspections. The purpose of the inspection is to determine that exterior elevated elements and their associated waterproofing elements are in a generally safe condition, adequate working order, and free from any hazardous condition caused by fungus, deterioration, decay, or improper alteration to the extent that the life, limb, health, property, safety, or welfare of the public or the occupants is not endangered. The person or business performing the inspection shall be hired by the owner of the building.

(b) For purposes of this section, the following terms have the following definitions:

(1) “Associated waterproofing elements” include flashings, membranes, coatings, and sealants that protect the load-bearing components of exterior elevated elements from exposure to water and the elements.

(2) “Exterior elevated element” means the following types of structures, including their supports and railings: balconies, decks, porches, stairways, walkways, and entry structures that extend beyond exterior walls of the building and which have a walking surface that is elevated more than six feet above ground level, are designed for human occupancy or use, and rely in whole or in substantial part on wood or wood-based products for structural support or stability of the exterior elevated element.

(3) “Load-bearing components” are those components that extend beyond the exterior walls of the building to deliver structural loads from the exterior elevated element to the building.

(c) The inspection required by this section shall at a minimum include:

(1) Identification of each type of exterior elevated element that, if found to be defective, decayed, or deteriorated to the extent that it does not meet its load requirements, would, in the opinion of the inspector, constitute a threat to the health or safety of the occupants.

(2) Assessment of the load-bearing components and associated waterproofing elements of the exterior elevated elements identified in paragraph (1) using methods allowing for evaluation of their performance by direct visual examination or comparable means of evaluating their performance. For purposes of this section, a sample of at least 15 percent of each type of exterior elevated element shall be inspected.

(3) The evaluation and assessment shall address each of the following as of the date of the evaluation:

(A) The current condition of the exterior elevated elements.

(B) Expectations of future performance and projected service life.

(C) Recommendations of any further inspection necessary.

(4) A written report of the evaluation stamped or signed by the inspector presented to the owner of the building or the owner’s designated agent within 45 days of completion of the inspection. The report shall include photographs, any test results, and narrative sufficient to establish a baseline of the condition of the components inspected that can be compared to the results of subsequent inspections. In addition to the evaluation required by this section, the report shall advise which, if any, exterior elevated element poses an immediate threat to the safety of the occupants, and whether preventing occupant access or conducting emergency repairs, including shoring, are necessary.

(d) The inspection shall be completed by January 1, 2025, and by January 1 every six years thereafter. The inspector conducting the inspection shall produce an initial report pursuant to paragraph (4) of subdivision (c) and, if requested by the owner, a final report indicating that any required repairs have been completed. A copy of any report that recommends immediate repairs, advises that any building assembly poses an immediate threat to the safety of the occupants, or that preventing occupant access or emergency repairs, including shoring, are necessary, shall be provided by the inspector to the owner of the building and to the local enforcement agency within 15 days of completion of the report. Subsequent inspection reports shall incorporate copies of prior inspection reports, including the locations of the exterior elevated elements inspected. Local enforcement agencies may determine whether any additional information is to be provided in the report and may require a copy of the initial or final reports, or both, be submitted to the local jurisdiction. Copies of all inspection reports shall be maintained in the building owner’s permanent records for not less than two inspection cycles, and shall be disclosed and delivered to the buyer at the time of any subsequent sale of the building.

(e) The inspection of buildings for which a building permit application has been submitted on or after January 1, 2019, shall occur no later than six years following issuance of a certificate of occupancy from the local jurisdiction and shall otherwise comply with the provisions of this section.

(f) If the property was inspected within three years prior to January 1, 2019, by an inspector as described in subdivision (a) and a report of that inspector was issued stating that the exterior elevated elements and associated waterproofing elements are in proper working condition and do not pose a threat to the health and safety of the public, no new inspection pursuant to this section shall be required until January 1, 2025.

(g) An exterior elevated element found by the inspector that is in need of repair or replacement shall be corrected by the owner of the building. No recommended repair shall be performed by a licensed contractor serving as the inspector. All necessary permits for repair or replacement shall be obtained from the local jurisdiction. All repair and replacement work shall be performed by a qualified and licensed contractor in compliance with all of the following:

(1) The recommendations of a licensed professional described in subdivision (a).

(2) Any applicable manufacturer’s specifications.

(3) The California Building Standards Code, consistent with subdivision (d) of Section 17922 of the Health and Safety Code.

(4) All local jurisdictional requirements.

(h) (1) An exterior elevated element that the inspector advises poses an immediate threat to the safety of the occupants, or finds preventing occupant access or emergency repairs, including shoring, or both, are necessary, shall be considered an emergency condition and the owner of the building shall perform required preventive measures immediately. Immediately preventing occupant access to the exterior elevated element until emergency repairs can be completed constitutes compliance with this paragraph. Repairs of emergency conditions shall comply with the requirements of subdivision (g), be inspected by the inspector, and reported to the local enforcement agency.

(2) The owner of the building requiring corrective work to an exterior elevated element that, in the opinion of the inspector, does not pose an immediate threat to the safety of the occupants, shall apply for a permit within 120 days of receipt of the inspection report. Once the permit is approved, the owner of the building shall have 120 days to make the repairs unless an extension of time is granted by the local enforcement agency.

(i) (1) The owner of the building shall be responsible for complying with the requirements of this section.

(2) If the owner of the building does not comply with the repair requirements within 180 days, the inspector shall notify the local enforcement agency and the owner of the building. If within 30 days of the date of the notice the repairs are not completed, the owner of the building shall be assessed a civil penalty based on the fee schedule set by the local authority of not less than one hundred dollars ($100) nor more than five hundred dollars ($500) per day until the repairs are completed, unless an extension of time is granted by the local enforcement agency.

(3) In the event that a civil penalty is assessed pursuant to this section, a building safety lien may be recorded in the county recorder’s office by the local jurisdiction in the county in which the parcel of land is located and from the date of recording shall have the force, effect, and priority of a judgment lien.

(j) (1) A building safety lien authorized by this section shall specify the amount of the lien, the name of the agency on whose behalf the lien is imposed, the street address, the legal description and assessor’s parcel number of the parcel on which the lien is imposed, and the name and address of the recorded owner of the building.

(2) In the event that the lien is discharged, released, or satisfied, either through payment or foreclosure, notice of the discharge containing the information specified in paragraph (1) shall be recorded by the governmental agency. A safety lien and the release of the lien shall be indexed in the grantor-grantee index.

(3) A building safety lien may be foreclosed by an action brought by the appropriate local jurisdiction for a money judgment.

(4) Notwithstanding any other law, the county recorder may impose a fee on the city to reimburse the costs of processing and recording the lien and providing notice to the owner of the building. A city may recover from the owner of the building any costs incurred regarding the processing and recording of the lien and providing notice to the owner of the building as part of its foreclosure action to enforce the lien.

(k) The continued and ongoing maintenance of exterior elevated elements in a safe and functional condition in compliance with these provisions shall be the responsibility of the owner of the building.

(l) Local enforcement agencies shall have the ability to recover enforcement costs associated with the requirements of this section.

(m) For any building subject to the provisions of this section that is proposed for conversion to condominiums to be sold to the public after January 1, 2019, the inspection required by this section shall be conducted prior to the first close of escrow of a separate interest in the project and shall include the inspector’s recommendations for repair or replacement of any exterior elevated element found to be defective, decayed, or deteriorated to the extent that it does not meet its load requirements, and would, in the opinion of the inspector, constitute a threat to the health or safety of the occupants. The inspection report and written confirmation by the inspector that any repairs or replacements recommended by the inspector have been completed shall be submitted to the Department of Real Estate by the proponent of the conversion and shall be a condition to the issuance of the final public report. A complete copy of the inspection report and written confirmation by the inspector that any repairs or replacements recommended by the inspector have been completed shall be included with the written statement of defects required by Section 1134 of the Civil Code, and provided to the local jurisdiction in which the project is located. The inspection, report, and confirmation of completed repairs shall be a condition of the issuance of a final inspection or certificate of occupancy by the local jurisdiction.

(n) This section shall not apply to a common interest development, as defined in Section 4100 of the Civil Code.

(o) The governing body of any city, county, or city and county, may enact ordinances or laws imposing requirements greater than those imposed by this section.

SEC. 3.

 No reimbursement is required by this act pursuant to Section 6 of Article XIII B of the California Constitution because a local agency or school district has the authority to levy service charges, fees, or assessments sufficient to pay for the program or level of service mandated by this act, within the meaning of Section 17556 of the Government Code.


Senate Bill No. 326

CHAPTER 207

An act to amend Section 6150 of, and to add Sections 5551 and 5986 to, the Civil Code, relating to civil law.

[ Approved by Governor August 30, 2019. Filed with Secretary of State August 30, 2019. ]

LEGISLATIVE COUNSEL’S DIGEST

SB 326, Hill. Common interest developments.

The Davis-Stirling Common Interest Development Act governs the management and operation of common interest developments. Existing law also sets forth the duties and responsibilities of the association and the owners of the separate interests with regard to maintenance and repair of common and exclusive use areas, as defined. Unless otherwise provided in the common interest development declaration, the association is generally responsible for maintaining, repairing, and replacing the common area, and the owner of each separate interest is responsible for maintaining that separate interest and any exclusive use common area appurtenant to that interest.

This bill would require the association of a condominium project to cause a reasonably competent and diligent visual inspection of exterior elevated elements, defined as the load-bearing components and associated waterproofing systems, as specified, to determine whether the exterior elevated elements are in a generally safe condition and performing in compliance with applicable standards. The bill would require the inspector to submit a report to the board of the association providing specified information, including the current physical condition and remaining useful life of the load-bearing components and associated waterproofing systems. The bill would require the inspector to provide a copy of the inspection report to the association immediately upon completion of the report, and to the local code enforcement agency within 15 days of completion of the report, if, after inspection of any exterior elevated element, the inspector advises that the exterior elevated element poses an immediate threat to the safety of the occupants. The bill would require the association to take preventive measures immediately upon receiving the report, including preventing occupant access to the exterior elevated element until repairs have been inspected and approved by the local enforcement agency. The bill would authorize local enforcement agencies to recover enforcement costs associated with these requirements from the association. The bill would authorize the association board to enact rules or bylaws imposing requirements greater than those imposed by these provisions.

The act provides that an association has standing to institute, defend, settle, or intervene in litigation, arbitration, mediation, or administrative proceedings in its own name as the real party in interest and without joining with its members in specified matters, including enforcement of the governing documents.

The bill would provide that, subject to compliance with other specified provisions described below, and notwithstanding any provision to the contrary in the governing documents, a board has the authority to commence legal proceedings against a declarant, developer, or builder of a common interest development, except as specified. The bill would, with certain exceptions, prohibit an association’s governing documents from limiting a board’s authority to commence legal proceedings against a declarant, developer, or builder of a common interest development. The bill would make these provisions applicable to governing documents, irrespective of when they were recorded, and claims initiated before the effective date of this bill, except if those claims have been resolved through an executed settlement, a final arbitration decision, or a final judicial decision on the merits.

The act requires the board, prior to the filing of certain civil actions by the association against the declarant or developer, or within 30 days of filing the civil action if the association has reason to believe that the applicable statute of limitations will expire before the association files the civil action, to provide members of the association a written notice specifying, among other things, that a meeting will take place to discuss problems that may lead to the filing of a civil action.

This bill would require that notice to inform members that the potential impacts of filing a civil action, including financial, to the association and its members will also be discussed.

DIGEST KEY

Vote: majority   Appropriation: no   Fiscal Committee: no   Local Program: no  


BILL TEXT

THE PEOPLE OF THE STATE OF CALIFORNIA DO ENACT AS FOLLOWS:

SECTION 1.

 Section 5551 is added to the Civil Code, to read:

5551.

 (a) For purposes of this section, the following definitions apply:

(1) “Associated waterproofing systems” include flashings, membranes, coatings, and sealants that protect the load-bearing components of exterior elevated elements from exposure to water.

(2) “Exterior elevated elements” mean the load-bearing components together with their associated waterproofing system.

(3) “Load-bearing components” means those components that extend beyond the exterior walls of the building to deliver structural loads to the building from decks, balconies, stairways, walkways, and their railings, that have a walking surface elevated more than six feet above ground level, that are designed for human occupancy or use, and that are supported in whole or in substantial part by wood or wood-based products.

(4) “Statistically significant sample” means a sufficient number of units inspected to provide 95 percent confidence that the results from the sample are reflective of the whole, with a margin of error of no greater than plus or minus 5 percent.

(5) “Visual inspection” means inspection through the least intrusive method necessary to inspect load-bearing components, including visual observation only or visual observation in conjunction with, for example, the use of moisture meters, borescopes, or infrared technology.

(b) (1) At least once every nine years, the board of an association of a condominium project shall cause a reasonably competent and diligent visual inspection to be conducted by a licensed structural engineer or architect of a random and statistically significant sample of exterior elevated elements for which the association has maintenance or repair responsibility.

(2) The inspection shall determine whether the exterior elevated elements are in a generally safe condition and performing in accordance with applicable standards.

(c) Prior to conducting the first visual inspection, the inspector shall generate a random list of the locations of each type of exterior elevated element. The list shall include all exterior elevated elements for which the association has maintenance or repair responsibility. The list shall be provided to the association for future use.

(d) The inspector shall perform the visual inspections in accordance with the random list generated pursuant to subdivision (c). If during the visual inspection the inspector observes building conditions indicating that unintended water or water vapor has passed into the associated waterproofing system, thereby creating the potential for damage to the load-bearing components, then the inspector may conduct a further inspection. The inspector shall exercise their best professional judgment in determining the necessity, scope, and breadth of any further inspection.

(e) Based upon the inspector’s visual inspections, further inspection, and construction and materials expertise, the inspector shall issue a written report containing the following information:

(1) The identification of the building components comprising the load-bearing components and associated waterproofing system.

(2) The current physical condition of the load-bearing components and associated waterproofing system, including whether the condition presents an immediate threat to the health and safety of the residents.

(3) The expected future performance and remaining useful life of the load-bearing components and associated waterproofing system.

(4) Recommendations for any necessary repair or replacement of the load-bearing components and associated waterproofing system.

(f) The report issued pursuant to subdivision (e) shall be stamped or signed by the inspector, presented to the board, and incorporated into the study required by Section 5550.

(g) (1) If, after inspection of any exterior elevated element, the inspector advises that the exterior elevated element poses an immediate threat to the safety of the occupants, the inspector shall provide a copy of the inspection report to the association immediately upon completion of the report, and to the local code enforcement agency within 15 days of completion of the report. Upon receiving the report, the association shall take preventive measures immediately, including preventing occupant access to the exterior elevated element until repairs have been inspected and approved by the local enforcement agency.

(2) Local enforcement agencies shall have the ability to recover enforcement costs associated with the requirements of this section from the association.

(h) Each subsequent visual inspection conducted under this section shall commence with the next exterior elevated element identified on the random list and shall proceed in order through the list.

(i) The first inspection shall be completed by January 1, 2025, and then every nine years thereafter in coordination with the reserve study inspection pursuant to Section 5550. All written reports shall be maintained for two inspection cycles as records of the association.

(j) (1) The association shall be responsible for complying with the requirements of this section.

(2) The continued and ongoing maintenance and repair of the load-bearing components and associated waterproofing systems in a safe, functional, and sanitary condition shall be the responsibility of the association as required by the association’s governing documents.

(k) The inspection of buildings for which a building permit application has been submitted on or after January 1, 2020, shall occur no later than six years following the issuance of a certificate of occupancy. The inspection shall otherwise comply with the provisions of this section.

(l) This section shall only apply to buildings containing three or more multifamily dwelling units.

(m) The association board may enact rules or bylaws imposing requirements greater than those imposed by this section.

(n) A local government or local enforcement agency may enact an ordinance or other rule imposing requirements greater than those imposed by this section.

SEC. 2.

 Section 5986 is added to the Civil Code, immediately following Section 5985, to read:

5986.

 (a) Subject to compliance with Section 6150, which requires the board to provide notice of a meeting with the members to discuss, among other things, problems that may lead to the filing of a civil action, before the board files a civil action against a declarant or other developer, or within 30 days after it files the action, if the association has reason to believe that the applicable statute of limitations will expire, and notwithstanding any provision to the contrary in the governing documents, the board shall have the authority to commence and pursue a claim, civil action, arbitration, prelitigation process pursuant to Section 6000 or Title 7 (commencing with Section 895) of Part 2 of Division 2, or other legal proceeding against a declarant, developer, or builder of a common interest development. If the board includes members appointed by, or affiliated with, the declarant, developer, or builder, the decision and authority to commence and pursue legal proceedings shall be vested solely in the nonaffiliated board members.

(b) The governing documents shall not impose any preconditions or limitations on the board’s authority to commence and pursue any claim, civil action, arbitration, prelitigation process pursuant to Section 6000 or Title 7 (commencing with Section 895) of Part 2 of Division 2, or other legal proceeding against a declarant, developer, or builder of a common interest development. Any limitation or precondition, including, but not limited to, requiring a membership vote as a prerequisite to, or otherwise providing the declarant, developer, or builder with veto authority over, the board’s commencement and pursuit of a claim, civil action, arbitration, prelitigation process, or legal proceeding against the declarant, developer, or builder, or any incidental decision of the board, including, but not limited to, retaining legal counsel or incurring costs or expenses, is unenforceable, null, and void. The failure to comply with those limitations or preconditions, if only, shall not be asserted as a defense to any claim or action described in this section.

(c) Notwithstanding subdivision (a) or (b), any provision in the governing documents imposing limitations or preconditions on the board’s authority to commence and pursue claims shall be valid and enforceable if the provision is adopted solely by the nondeclarant affiliated members of the association and the provision is adopted in accordance with the requirements necessary to amend the governing documents of the association.

(d) This section applies to all governing documents, whether recorded before or after the effective date of this section, and applies retroactively to claims initiated before the effective date of this section, except if those claims have been resolved through an executed settlement, a final arbitration decision, or a final judicial decision on the merits.

(e) Nothing in this section extends any applicable statute of limitation or repose to file or initiate any claim, civil action, arbitration, prelitigation process, or other legal proceeding. Nothing in this section shall affect any other obligations of an association contained in Title 7 (commencing with Section 895) of Part 2 of Division 2, or any other provision in the covenants, conditions, and restrictions of the association related to arbitration or other alternative dispute resolution procedures.

SEC. 3.

 Section 6150 of the Civil Code is amended to read:

6150.

 (a) Not later than 30 days before filing of any civil action by the association against the declarant or other developer of a common interest development for alleged damage to the common areas, alleged damage to the separate interests that the association is obligated to maintain or repair, or alleged damage to the separate interests that arises out of, or is integrally related to, damage to the common areas or separate interests that the association is obligated to maintain or repair, the board shall provide a written notice to each member of the association who appears on the records of the association when the notice is provided. This notice shall specify all of the following:

(1) That a meeting will take place to discuss problems that may lead to the filing of a civil action, in addition to the potential impacts thereof to the association and its members, including any financial impacts.

(2) The options, including civil actions, that are available to address the problems.

(3) The time and place of the meeting.

(b) Notwithstanding subdivision (a), if the association has reason to believe that the applicable statute of limitations will expire before the association files the civil action, the association may give the notice, as described above, within 30 days after the filing of the action.